13. Durability
13.1. Electrical Noise
No malfunction occurred when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp) was
added to a power supply line.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25 mm
Symbology: 9-digit Code-39
Quiet Zone: 10 mm
N/W Ratio: 1:2.5
Distance: 90 mm
Angle: α = 0° β = 15° γ = 0°
Curvature: R =
Power Supply Voltage: 5.0 V
13.2. Shock
13.2.1. Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three
times on each of 5 sides.
Figure 26: Drop test
13.2.2. Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor on
each of one corner, three edges, and six sides (10 drop tests in total).